Metso websites
Product Finder
Further information on this subject via email
 
kajaaniRM3 Operation

kajaaniRM3 New Wet End Sensor for Retention

 
 
 
 
 
 
 
 
 
 

The new kajaaniRM3 has versatile user-interfaces:
  • TCU (Transmitter Central Unit): to operate kajaaniRM3, the local interface
  • FieldCare™ based PC connection: for measurement data, configuration, calibration, diagnostics, and trending
  • DCS Connection through analog outputs: operator interface, for controls and alarms

Diagnostics as part of Life Cycle Services:
  • Configuration and diagnostics tools: full HART, DTM for FieldCare (complete)
  • Diagnostics: alarms, warnings, error log with time stamped events
Self Diagnostics:
  • Water calibration values (the best way to check the measurement drifting and capillary cleanliness)
  • Analysis of raw signals (continuously monitored), signal check to prevent drifting out of calibration area

I/O Connections:
  • Analog: default 2 analog outputs 4–20 mA + HART®, 4–20 mA, 18–35 VDC
  • Total ash consistency: external connection box (optional)
  • 4 additional analog outputs
  • Total and ash retention, floc signal, ash content
  • Binary: 2 binary inputs
  • Machine shut down info and grade